Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
RSC Adv ; 13(2): 844-852, 2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36686907

RESUMO

A simple, cost-effective, and efficient differential pulse voltammetric (DPV) assay for monitoring spiramycin adipate (SPA) in its dosage forms, urine, and milk samples at an activated glassy carbon electrode (GCE) was developed. GCE was electrochemically activated by anodization at a high positive voltage (2.5 V). The activated glassy carbon electrode (AGCE) was surface characterized, optimized, and utilized for the electrochemical assay of SPA. The electrochemical behavior of the AGCEs was investigated using cyclic voltammetry (CV) which shows a remarkable increase in the anodic peak of SPA in comparison with GCE. This behavior reflects a remarkable increase in the electrocatalytic oxidation of SPA at AGCE. The impacts of various parameters such as scan rate, accumulation time, and pH were investigated. The analytical performance of the activated glassy carbon electrodes was studied utilizing DPV. Under optimum conditions, the oxidation peak current exhibited two linear ranges of 80 nm to 0.8 µM and 0.85-300 µM with a lower limit of detection (LOD) of 20 nM. The developed assay exhibited high sensitivity, excellent repeatability, and good selectivity. Additionally, the developed SPA-sensitive modified GCE was successfully applied for SPA assay in its pharmaceutical dosage form and diluted biological fluids as well, with satisfactory recovery results which correlated well with the results obtained using spectrophotometry.

2.
RSC Adv ; 12(45): 28878-28885, 2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36320724

RESUMO

The development of new mesoporous frits for reference electrodes to overcome the limitations of cross-contamination and screening effect is essential for many electrochemical measurements. Available frit-based reference electrodes (e.g., mesoporous, microporous) still suffer from cross-contamination and/or errors in electrochemical measurements. In this work, a mesoporous glass-ceramic composite is prepared to mitigate such limitations. Mesoporous glass-ceramic frits were prepared from low-cost materials (i.e., borosilicate and kaolin) at relatively low temperatures (750-850 °C). The prepared glass-ceramic frits were characterized using scanning electron microscopy (SEM), impedance measurements, and nitrogen sorption isotherms. The developed mesoporous glass-ceramic composites are characterized by a high chemical resistance against corrosive materials and a low thermal expansion. Reference electrodes constructed with the developed mesoporous glass-ceramic frits exhibited a low flow rate of 0.002 ± 0.001 to 0.41 ± 0.06 µL h-1 and high potential stability as well as very small potential drift of -2.4 ± 0.2 to -4.9 ± 0.2 µV h-1. Mesoporous glass-ceramic based reference electrodes exhibited average potential variations of 13 ± 3 mV over the concentration range of 1 mM to 0.1 M KCl. This indicates that mesoporous glass-ceramic frit-based reference electrodes exhibited a much lower flow rate compared to available microporous frit-based reference electrodes. Moreover, the developed mesoporous ceramic-based reference electrodes exhibited a 4-15-fold improvement in potential variations and a large improvement in potential stability in comparison with the reported mesoporous-frit-based reference electrodes.

3.
ACS Omega ; 7(38): 34127-34135, 2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36188318

RESUMO

Glassy carbon electrode (GCE) was electrochemically activated using a repetitive cyclic voltammetric technique to develop an activated glassy carbon electrode (AGCE). The developed AGCE was optimized and utilized for the electrochemical assay of 4-nitrophenol (4-NP) and dopamine (DA). Cyclic voltammetry (CV) was employed to investigate the electrochemical behavior of the AGCE. Compared to the bare GCE, the developed AGCE exhibits a significant increase in redox peak currents of 4-NP and DA, which indicates that the AGCE significantly improves the electrocatalytic reduction of 4-NP and oxidation of DA. The electrochemical signature of the activation process could be directly associated with the formation of oxygen-containing surface functional groups (OxSFGs), which are the main reason for the improved electron transfer ability and the enhancement of the electrocatalytic activity of the AGCE. The effects of various parameters on the voltammetric responses of the AGCE toward 4-NP and DA were studied and optimized, including the pH, scan rate, and accumulation time. Differential pulse voltammetry (DPV) was also utilized to investigate the analytical performance of the AGCE sensing platform. The optimized AGCE exhibited linear responses over the concentration ranges of 0.04-65 µM and 65-370 µM toward 4-NP with a lower limit of detection (LOD) of 0.02 µM (S/N = 3). Additionally, the AGCE exhibited a linear responses over the concentration ranges of 0.02-1.0 and 1.0-100 µM toward DA with a lower limit of detection (LOD) of 0.01 µM (S/N = 3). Moreover, the developed AGCE-based 4-NP and DA sensors are distinguished by their high sensitivity, excellent selectivity, and repeatability. The developed sensors were successfully applied for the determination of 4-NP and DA in real samples with satisfactory recovery results.

4.
Head Neck ; 43(7): 2216-2239, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33860981

RESUMO

We investigated safety and efficacy of transoral robotic surgery (TORS) for base of tongue (BOT) reduction in obstructive sleep apnea syndrome (OSAS) patients. PubMed, Cochrane Library, and Scopus were searched. A meta-analysis was performed. Random effects models were used. Thirty-one cohorts met our criteria (1693 patients). The analysis was based mostly on retrospective studies. The summary estimate of the reduction of Apnea-Hypoxia Index (AHI) was 24.25 abnormal events per hour (95% CI: 21.69-26.81) and reduction of Epworth Sleepiness Scale (ESS) was 7.92 (95% CI: 6.50-9.34). The summary estimate of increase in lowest O2 saturation was 6.04% (95% CI: 3.05-9.03). The success rate of TORS BOT reduction, either alone or combined with other procedures, was 69% (95% CI: 64-79). The majority of studies reported low level of evidence but suggested that TORS BOT reduction may be a safe procedure associated with improvement of AHI, ESS, and lowest O2 saturation.


Assuntos
Procedimentos Cirúrgicos Robóticos , Apneia Obstrutiva do Sono , Humanos , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Sono , Apneia Obstrutiva do Sono/cirurgia , Língua/cirurgia , Resultado do Tratamento
5.
Environ Sci Pollut Res Int ; 28(6): 6830-6842, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33011948

RESUMO

Cardiovascular diseases are key complications primarily associated with hyperthyroidism disorders. The present study sought to ameliorate hyperthyroidism-mediated cardiovascular inflammations and related oxidative stress paradigms in experimental rats using the broadly distributed green seaweed Ulva fasciata. Forty-eight adult male albino rats were recruited and randomly classified into six groups. Hyperthyroidism was stimulated using L-thyroxine sodium at a dose of 100 µg/kg i.p. for 3 weeks daily. Further, 200 mg/kg b.wt. concentration of the U. fasciata methanolic (U. fasciata-MeOH) extract was the recommended dose and administrated orally to the hyperthyroid rats. The standard commercial drug "propranolol hydrochloride" was also tested at a dose of 10 mg/kg i.p. to compare the findings obtained from the seaweed extract. A combined treatment with the U. fasciata-MeOH extract and propranolol hydrochloride was also assessed. Our results implied that the treatment of hyperthyroid rats with the U. fasciata-MeOH extract significantly reduced serum levels of the thyroid hormones T3 and T4, proinflammatory cytokines (TNF-α, MPO, and CRP), triglycerides and total cholesterol, as well as the cardiac biomarkers CK-MB, LDH, and troponin to thresholds close to those of the standard drug. In addition, levels of high-density lipoprotein cholesterol (HDL-C) and interleukin 10 (IL-10) were significantly upregulated. Hyperthyroid rats only treated with propranolol hydrochloride, or with a combination of the drug and the seaweed extract, conferred the same observations. Histopathological architecture boosted our interesting findings where the myocardium tissues in hyperthyroid rats, administrated the U. fasciata-MeOH extract or/and propranolol hydrochloride, exhibited more or less a normal structure as the control, reflecting the potential cardiovascular recovery exerted by this seaweed extract. In vitro DPPH, ABTS, and FRAP antioxidant assays of the U. fasciata-MeOH extract showed an outstanding ROS-scavenging potential. HPLC analysis of the U. fasciata-MeOH extract unraveled an inestimable valuable array of phenolics (mainly p-coumaric, gallic, ferulic, chlorogenic, and syringic acids) and flavonoids (hesperidin, kaempferol, catechin, quercetin, and rutin). Conclusively, the seaweed U. fasciata is a profitable source of antioxidant polyphenolics characterized by having a pharmaceutical potential against hyperthyroidism-linked cardiovascular inflammations and oxidative stress patterns due to their substantial free radical quenching properties, and also via regulating the signalling pathways of the proinflammatory, lipid profile, and cardiac biomarkers.


Assuntos
Hipertireoidismo , Alga Marinha , Ulva , Animais , Hipertireoidismo/tratamento farmacológico , Inflamação/tratamento farmacológico , Masculino , Ratos , Tiroxina
6.
Anal Chem ; 92(11): 7947-7954, 2020 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-32383384

RESUMO

Several reports in the literature deal with the modification of glassy carbon electrode (GCE) surface via electropolymerization of some organic monomers, particularly p-aminobenzenesulfonic acid (p-ABSA) and l-cysteine using intensive oxidative conditions, and attributed the improved electrocatalytic activities toward various analytes to the formation of the electropolymerized layer. What is the real cause for this improvement in electrocatalytic activity? Is it because of the electrochemical activation process of GCE or electropolymerization? Combining a set of surface and electrochemical characterization techniques, we first showed that the electrochemical peaks previously assigned in many reports to electropolymerization processes at the surface of GCE correspond to electrochemical activation of the GCE surface. We further demonstrated that the anodization of GCE at high voltage causes activation of its surface and the formation of surface functional groups (SFGs). In fact, those SFGs are found to be the main reason for the enhancement in electrocatalytic activity of the activated GCE (AGCE). The surface features of the modified electrodes were characterized by Raman spectroscopy, attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDX). The electrochemical behavior was investigated using cyclic voltammetry (CV). The analytical performance of AGCE toward dopamine (DA) was assessed using differential pulse voltammetry (DPV). As compared to the previously reported dopamine electrochemical sensors assuming such electropolymerization processes, the AGCE showed analytical performance practically similar to that of these sensors. This further confirms that the enhancement in electrocatalytic activity is due to the electrochemical activation of the GCE surface.

7.
Spectrochim Acta A Mol Biomol Spectrosc ; 224: 117395, 2020 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-31362184

RESUMO

This work describes the development of highly sensitive as well as simple two spectrofluorimetric methods for the determination of apramycin sulfate. The first method depends on measuring the inherent native fluorescence of the aqueous neutral solution of the drug at 388 nm (λex 335 nm). While the second method mainly based on enhancing the native fluorescence intensity of the drug using sodium dodecyl sulfate (SDS) micellar media by about 4 fold enhancement. The fluorescence intensity - concentration relationship for the two methods was found rectilinear over the concentration range 1.0-100.0 and 0.1-20.0 µg/mL for the first and second method respectively. The limit of detection for method I and II were 0.05 and 0.02 µg/mL respectively. The proposed methods can be effectively connected for the assurance of the medication without impedances from common normal excipients. Furthermore, the two methods were high sensitive enough for the assurance of the drug in spiked milk samples with high percentage recoveries.


Assuntos
Leite/química , Nebramicina/análogos & derivados , Espectrometria de Fluorescência/métodos , Animais , Resíduos de Drogas/análise , Concentração de Íons de Hidrogênio , Limite de Detecção , Modelos Lineares , Nebramicina/análise , Reprodutibilidade dos Testes , Drogas Veterinárias/análise
8.
Artigo | WPRIM (Pacífico Ocidental) | ID: wpr-831283

RESUMO

There are many ways to categorize surgery for obstructive sleep apnea (OSA), one of which is to distinguish between intrapharyngeal and extrapharyngeal procedures. While the general otolaryngologist treating OSA is familiar with intrapharyngeal procedures, such as uvulopalatopharyngoplasty and tongue base reduction, extrapharyngeal sleep operations such as maxillomandibular advancement (MMA) and upper airway stimulation (UAS) have evolved rapidly in the recent decade and deserve a dedicated review. MMA and UAS have both shown predictable high success rates with low morbidity. Each approach has unique strengths and limitations, and for the most complex of OSA patients, the two in combination complement each other. Extrapharyngeal airway operations are critical for achieving favorable outcomes for sleep surgeons.

9.
Artif Cells Nanomed Biotechnol ; 47(1): 1533-1542, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31007071

RESUMO

Poly (methyl methacrylate) (PMMA) is basically biocompatible polyester with high resistance to chemical hydrolysis, and high drug permeability and the most important characteristics of PMMA is that it does not produce any toxicity. There is not much information about PMMA action on the colon cancer cells. In the present study, we have synthesized PMMA nanoparticles. The distribution pattern of PMMA particles was analysed by Zeta sizer and the size of the particles was calculated by using quasi elastic light scattering (QELS). The surface structure and the morphology of PMMA were characterized by transmission electron microscope (TEM) and scanning electron microscope (SEM), respectively. We have also analysed their effects on cancerous cells (human colorectal carcinoma cells, HCT-116) and normal, healthy cells (human embryonic kidney cells, HEK-293) by using morphometric, MTT, DAPI and wound healing methods. We report that PMMA particles inhibited the cancer cell viability in a dose-dependent manner. The lower dose (1.0 µg/ml) showed a moderate decrease in cancer cell viability, whereas higher dosages (2.5 µg/ml, 5.0 µg/mL and 7.5 µg/mL) showed steadily decrease in the cancer cell viability. We also report that PMMA is highly selective to cancerous cells (HCT-116), as we did not find any action on the normal healthy cells (HEK-293). In conclusion, our results suggest PMMA particles are potential biomaterials to be used in the treatment of colon cancer.


Assuntos
Neoplasias do Colo/patologia , Polimetil Metacrilato/química , Polimetil Metacrilato/farmacologia , Núcleo Celular/efeitos dos fármacos , Núcleo Celular/patologia , Proliferação de Células/efeitos dos fármacos , Sistemas de Liberação de Medicamentos , Células HCT116 , Células HEK293 , Humanos , Nanopartículas/química , Tamanho da Partícula , Polimetil Metacrilato/metabolismo , Cicatrização/efeitos dos fármacos
10.
Analyst ; 142(17): 3241-3249, 2017 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-28795694

RESUMO

Electrospray ionization mass spectrometry ESI-MS is a powerful technique for the characterization of macromolecules and their noncovalent binding with guest ions. We herein evaluate the feasibility of using ESI-MS as a screening tool for predicting potentiometric selectivities of ionophores. Ion-selective electrodes based on the cyclic peptide, cyclosporin A, were developed, and their potentiometric selectivity pattern was evaluated. Optimized electrodes demonstrated near-Nernstian slopes with micromolar detection limits toward calcium. ESI-MS and ESI-MS/MS were employed to determine the relative association strengths of cyclosporin A with various cations. The observed MS intensities of ion-ionophore complexes correlate favorably with the potentiometric selectivity pattern that was demonstrated by cyclosporin-based electrodes. This correlation was found to hold true for other established ionophores, such as valinomycin and benzo-18-crown-6. Taken together, these experiments demonstrate that mass spectrometry could be used to predict the selectivity patterns of new ionophores for potentiometric and optical ion sensors. Further, this approach could be useful in screening mixtures or libraries of newly-synthesized compounds to identify selective ionophores.

11.
Carbohydr Polym ; 134: 687-94, 2015 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-26428173

RESUMO

Bacterial cellulose (BC) and heparin-modified bacterial cellulose (HBC) were utilized to enhance the biocompatibility of highly thrombogenic PVC-based potassium and calcium membrane electrodes. Three types of membrane electrodes were prepared: (1) conventional PVC electrode (control), (2) PVC-based electrode sandwiched with bacterial cellulose membrane (BC-PVC), and (3) PVC-based electrode sandwiched with heparin-modified bacterial cellulose membrane (HBC-PVC). The potentiometric response characteristics of the modified potassium and calcium membrane electrodes (BC-PVC and HBC-PVC) were compared with those of the control PVC-based potassium and calcium selective electrode, respectively. Response characteristics of the modified membrane electrodes were comparable to the control PVC membrane electrode. The platelet adhesion investigations indicated that (BC) and (HBC) layers are less thrombogenic compared to PVC. Therefore, use of BC or HBC would enable the enhancement of the biocompatibility of PVC-based membrane electrodes for potassium and calcium while practically maintaining the overall electrochemical performance of the PVC sensing film.


Assuntos
Materiais Biocompatíveis/química , Celulose/química , Gluconacetobacter xylinus/química , Heparina/química , Animais , Materiais Biocompatíveis/farmacologia , Eletrodos , Membranas Artificiais , Agregação Plaquetária/efeitos dos fármacos , Potássio/química , Ovinos
12.
Anat Rec (Hoboken) ; 298(6): 1036-46, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25998638

RESUMO

BACKGROUND: CT scanning of ancient human remains has the potential to provide insights into health and diseases. While Egyptian mummies have undergone CT scans in prior studies, a systematic survey of the orthopedic conditions afflicting a group of these ancient individuals has never been carried out. METHODS: We performed whole body CT scanning on 52 ancient Egyptian mummies using technique comparable to that of medical imaging. All of the large joints and the spine were systematically examined and osteoarthritic (OA) changes were scored 0-4 using Kellgren and Lawrence classification. RESULTS: The cruciate ligaments and menisci could be identified frequently. There were much more frequent OA changes in the spine (25 mummies) than in the large joints (15 cases of acromioclavicular and/or glenohumeral joint OA changes, five involvement of the ankle, one in the elbow, four in the knee, and one in the hip). There were six cases of scoliosis. Individual mummies had the following conditions: juvenile aseptic necrosis of the hip (Perthes disease), stage 4 osteochondritis dissecans of the knee, vertebral compression fracture, lateral patella-femoral joint hyper-compression syndrome, severe rotator cuff arthropathy, rotator cuff impingement, hip pincer impingement, and combined fracture of the greater trochantor and vertebral bodies indicating obvious traumatic injury. This report includes the most ancient discovery of several of these syndromes. CONCLUSIONS: Ancient Egyptians often suffered painful orthopedic conditions. The high frequency of scoliosis merits further study. The pattern of degenerative changes in the spine and joints may offer insights into activity levels of these people.


Assuntos
Múmias/diagnóstico por imagem , Osteoartrite/diagnóstico por imagem , Escoliose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Adolescente , Adulto , Criança , Antigo Egito , Feminino , História Antiga , Humanos , Masculino , Pessoa de Meia-Idade , Múmias/história , Osteoartrite/história , Radiografia , Escoliose/história , Adulto Jovem
13.
Talanta ; 118: 147-55, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24274282

RESUMO

Novel uranyl selective polymeric membrane electrodes were prepared using three different low-cost and commercially available Cyanex extractants namely, bis(2,4,4-trimethylpentyl) phosphinic acid [L1], bis(2,4,4-trimethylpentyl) monothiophosphinic acid [L2] and bis(2,4,4-trimethylpentyl) dithiophosphinic acid [L3]. Optimization and performance characteristics of the developed Cyanex based polymer membrane electrodes were determined. The influence of membrane composition (e.g., amount and type of ionic sites, as well as type of plasticizer) on potentiometric responses of the prepared membrane electrodes was studied. Optimized Cyanex-based membrane electrodes exhibited Nernstian responses for UO2(2+) ion over wide concentration ranges with fast response times. The optimized membrane electrodes based on L1, L2 and L3 exhibited Nernstian responses towards uranyl ion with slopes of 29.4, 28.0 and 29.3 mV decade(-1), respectively. The optimized membrane electrodes based on L1-L3 showed detection limits of 8.3 × 10(-5), 3.0 × 10(-5) and 3.3 × 10(-6) mol L(-1), respectively. The selectivity studies showed that the optimized membrane electrodes exhibited high selectivity towards UO2(2+) ion over large number of other cations. Membrane electrodes based on L3 exhibited superior potentiometric response characteristics compared to those based on L1 and L2 (e.g., widest linear range and lowest detection limit). The analytical utility of uranyl membrane electrodes formulated with Cyanex extractant L3 was demonstrated by the analysis of uranyl ion in different real samples for nuclear safeguards verification purposes. The results obtained using direct potentiometry and flow-injection methods were compared with those measured using the standard UV-visible and inductively coupled plasma spectroscopic methods.


Assuntos
Eletrodos Seletivos de Íons , Membranas Artificiais , Centrais Nucleares , Compostos Organotiofosforados/química , Polímeros/química , Compostos de Urânio/análise , Análise de Injeção de Fluxo , Concentração de Íons de Hidrogênio , Potenciometria , Espectrofotometria Ultravioleta
14.
Carbohydr Polym ; 99: 783-90, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24274570

RESUMO

Heparin-modified chitosan (H-chitosan) membrane was utilized to enhance biocompatibility of sodium selective membrane electrode based on the highly thrombogenic polyvinyl chloride (PVC). Sodium ion sensing film was prepared using PVC, sodium ionophore-X, potassium tetrakis(chlorophenyl)-borate, and o-nitrophenyloctylether. The PVC-based sensing film was sandwiched to chitosan or H-chitosan to prevent platelet adhesion on the surface of PVC. Potentiometric response characteristics of PVC-chitosan and PVC-H-chitosan membrane electrodes were found to be comparable to that of a control PVC based sodium-selective electrode. This indicates that chitosan and H-chitosan layers do not alter the response behaviour of the PVC-based sensing film. Biocompatibility of H-chitosan was confirmed by in vitro platelet adhesion study. The platelet adhesion investigations indicated that H-chitosan film is less thrombogenic compared to PVC, which could result in enhancement of biocompatibility of sodium selective membrane electrodes based on PVC, while maintaining the overall electrochemical performance of the PVC-based sensing film.


Assuntos
Quitosana/química , Hemostáticos/química , Heparina/química , Cloreto de Polivinila/química , Potenciometria/instrumentação , Sódio/análise , Animais , Plaquetas/citologia , Plaquetas/efeitos dos fármacos , Cátions Monovalentes , Quitosana/análogos & derivados , Quitosana/farmacologia , Eletrodos , Éteres/química , Membranas Artificiais , Adesividade Plaquetária/efeitos dos fármacos , Potenciometria/métodos , Carneiro Doméstico , Ionóforos de Sódio/química , Tetrafenilborato/análogos & derivados , Tetrafenilborato/química
15.
Lancet ; 381(9873): 1211-22, 2013 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-23489753

RESUMO

BACKGROUND: Atherosclerosis is thought to be a disease of modern human beings and related to contemporary lifestyles. However, its prevalence before the modern era is unknown. We aimed to evaluate preindustrial populations for atherosclerosis. METHODS: We obtained whole body CT scans of 137 mummies from four different geographical regions or populations spanning more than 4000 years. Individuals from ancient Egypt, ancient Peru, the Ancestral Puebloans of southwest America, and the Unangan of the Aleutian Islands were imaged. Atherosclerosis was regarded as definite if a calcified plaque was seen in the wall of an artery and probable if calcifications were seen along the expected course of an artery. FINDINGS: Probable or definite atherosclerosis was noted in 47 (34%) of 137 mummies and in all four geographical populations: 29 (38%) of 76 ancient Egyptians, 13 (25%) of 51 ancient Peruvians, two (40%) of five Ancestral Puebloans, and three (60%) of five Unangan hunter gatherers (p=NS). Atherosclerosis was present in the aorta in 28 (20%) mummies, iliac or femoral arteries in 25 (18%), popliteal or tibial arteries in 25 (18%), carotid arteries in 17 (12%), and coronary arteries in six (4%). Of the five vascular beds examined, atherosclerosis was present in one to two beds in 34 (25%) mummies, in three to four beds in 11 (8%), and in all five vascular beds in two (1%). Age at time of death was positively correlated with atherosclerosis (mean age at death was 43 [SD 10] years for mummies with atherosclerosis vs 32 [15] years for those without; p<0·0001) and with the number of arterial beds involved (mean age was 32 [SD 15] years for mummies with no atherosclerosis, 42 [10] years for those with atherosclerosis in one or two beds, and 44 [8] years for those with atherosclerosis in three to five beds; p<0·0001). INTERPRETATION: Atherosclerosis was common in four preindustrial populations including preagricultural hunter-gatherers. Although commonly assumed to be a modern disease, the presence of atherosclerosis in premodern human beings raises the possibility of a more basic predisposition to the disease. FUNDING: National Endowment for the Humanities, Paleocardiology Foundation, The National Bank of Egypt, Siemens, and St Luke's Hospital Foundation of Kansas City.


Assuntos
Aterosclerose/história , Múmias/patologia , Adulto , Fatores Etários , Alaska/etnologia , Aterosclerose/etnologia , Egito/etnologia , Feminino , História do Século XV , História do Século XVI , História do Século XVII , História do Século XVIII , História do Século XIX , História do Século XX , História Antiga , História Medieval , Humanos , Masculino , Peru/etnologia , Sudoeste dos Estados Unidos/etnologia , Tomografia Computadorizada por Raios X , Calcificação Vascular/etnologia , Calcificação Vascular/história
16.
Artigo em Inglês | MEDLINE | ID: mdl-22813990

RESUMO

Novel mononuclear Zn(II) and Al(III) complexes were synthesized from the reactions of Zn(OAc)(2).2H(2)O and anhydrous AlCl(3) with neutral N2O2 donor tetradentate Schiff bases; N,N'bis(salicylaldehyde)4,5-dimethyl-1,2-phenylenediamine (H(2)L(1)) and N,N'bis(salicylaldehyde)4,5-dichloro-1,2-phenylenediamine (H(2)L(2)). The new complexes were fully characterized by using micro analyses (CHN), FT-IR, (1)H NMR, UV-Vis spectra and thermal analysis. The analytical data have been showed that, the stoichiometry of the complexes is 1:1. Spectroscopic data suggested tetrahedral and square pyramidal geometries for Zn(II) and Al(III) complexes, respectively. The synthesized Zn(II), and Al(III) complexes exhibited intense fluorescence emission in the visible region upon UV-excitation in methylene chloride solution at ambient temperature. This high fluorescence emission was assigned to the strong coordination of the ligands to the small and the highly charged Zn(II) and Al(III) ions. Such strong coordination seems to extend the π-conjugation of the complexes. Thermal analysis measurements indicated that the complexes have good thermal stability. As a potential application the biological activity (e.g., antimicrobial action) of the prepared ligands and complexes was assessed by in-vitro testing of their effect on the growth of various strains of bacteria and fungi.


Assuntos
Alumínio/farmacologia , Complexos de Coordenação/síntese química , Complexos de Coordenação/farmacologia , Luminescência , Bases de Schiff/síntese química , Bases de Schiff/farmacologia , Zinco/farmacologia , Absorção , Alumínio/química , Antibacterianos/síntese química , Antibacterianos/química , Antibacterianos/farmacologia , Antifúngicos/síntese química , Antifúngicos/química , Antifúngicos/farmacologia , Bactérias/efeitos dos fármacos , Complexos de Coordenação/química , Fungos/efeitos dos fármacos , Ligantes , Espectroscopia de Ressonância Magnética , Testes de Sensibilidade Microbiana , Bases de Schiff/química , Espectrometria de Fluorescência , Espectrofotometria Ultravioleta , Espectroscopia de Infravermelho com Transformada de Fourier , Termogravimetria , Zinco/química
17.
Anal Sci ; 25(7): 911-7, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19609032

RESUMO

A poly(vinyl chloride) matrix membrane sensor for the selective determination of thiocyanate has been developed based on the use of copper(II)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex (Cu-PADAP) as a novel charged carrier, and o-nitrophenyloctyl ether (o-NPOE) as a solvent mediator. The sensor displays a significantly enhanced response towards SCN(-) ions over the concentration range 7.0 x 10(-6) to 1.0 x 10(-2) mol L(-1) with a detection limit of 5.6 x 10(-6) mol L(-1) and a calibration slope of -57.5 +/- 0.5 mV decade(-1). The sensor exhibits a long life-span, long-term stability, high reproducibility, and a fast response time. The selectivity coefficients of some anions were calculated using the separate solutions method, and found to be in the following order: SCN(-) > ClO(4)(-) > I(-) > Sal(-) > NO(2)(-) > Br(-) > NO(3)(-) = CH(3)COO(-) > Cl(-) > SO(4)(2-) = PO(4)(3-). The effects of the pH and ionic membrane additives (e.g. tridodecylmethylammonium chloride, TDMAC and potassium tetrakis[bis(3,5-trifluoromethyl)phenyl] borate, KTFPB) were examined. The sensor was used for the determination of SCN(-) ions in saliva and urine samples collected from some smoker and non-smoker donors. The developed sensor was also applied to determine the cyanide content in electroplating waste water samples after its conversion into thiocyanate. The application of the sensor to monitor the potentiometric titration of Ag(+) and Hg(2+) using SCN(-) resulted in sharp inflection breaks at the equivalent points. The data obtained using the proposed sensor correlate very well with results collected using the standard methods of thiocyanate, cyanide and metal analysis.


Assuntos
Química Analítica/instrumentação , Cianetos/análise , Membranas Artificiais , Metais/análise , Cloreto de Polivinila/química , Tiocianatos/análise , Adulto , Idoso , Cianetos/química , Análise de Injeção de Fluxo , Humanos , Pessoa de Meia-Idade , Compostos Organometálicos/química , Potenciometria , Saliva/química , Tiocianatos/química , Tiocianatos/urina , Fatores de Tempo
18.
Anal Chim Acta ; 570(2): 176-85, 2006 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-17723397

RESUMO

Metallo-salens of cobalt(II) (Co-Sal), chromium(III) (Cr-Sal), and aluminum(III) (Al-Sal) are used as the active ionophores within plasticized poly(vinyl chloride) membranes. It is shown that central metal-ion plays a critical role in directing the ionophore selectivity. Polymer-membrane electrodes based on Co-Sal, Cr-Sal, and Al-Sal are demonstrated to exhibit enhanced responses and selectivity toward nitrite/thiocyanate, thiocyanate, and fluoride anions, respectively. The improved anion selectivity of the three ionophore systems is shown to deviate significantly from the classical Hofmeister pattern that is based only on ion lipophilicity. For example, optimized membrane electrodes for nitrite ion based on Co-Sal exhibit logK(Nitrite,Anion)(pot) values of -5.22, -4.66, -4.48, -2.5 towards bromide, perchlorate, nitrate, and iodide anions, respectively. Optimized membrane electrodes based on Co-Sal and Cr-Sal show near-Nernstian responses towards nitrite (-57.9+/-0.9 mV/decade) and thiocyanate (-56.9+/-0.8 mV/decade), respectively, with fast response and recovery times. In contrast, Al-Sal based membrane electrodes respond to fluoride ion in a super-Nernstian (-70+/-3 mV/decade) and nearly an irreversible mode. The operative response mechanism of Co-Sal, Cr-Sal, and Al-Sal membrane electrodes is examined using the effect of added ionic sites on the potentiometric response characteristics. It is demonstrated that addition of lipophilic anionic sites to membrane electrodes based on the utilized metallo-salens enhances the selectivity towards the primary ion, while addition of cationic sites resulted in Hofmeister selectivity patterns suggesting that the operative response mechanism is of the charged carrier type. Electron spin resonance (ESR) data indicates that Co(II) metal-ion center of Co-Sal ionophore undergoes oxidation to Co(III). This process leads to formation of a charged anion-carrier that is consistent with the response behavior obtained for Co-Sal based membrane electrodes.

19.
Anal Chem ; 77(20): 6719-28, 2005 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-16223262

RESUMO

More detailed analytical studies of a new fluoride-selective optical sensor based on the use of aluminum(III)-octaethylporphyrin and a lipophilic pH indicator (4',5'-dibromofluorescein octadecyl ester; ETH-7075) within a thin plasticized poly(vinyl chloride) film are reported. The sensor exhibits extraordinary optical selectivity for fluoride over a wide range of other anions, including anions with far more positive free energies of hydration (e.g., perchlorate, thiocyanate, nitrate, etc.). UV-visible spectrophotometric studies of the sensing films indicate that fluoride interacts with the Al(III) center of the porphyrin structure, yielding both a change in the Soret band lambda(max) of the porphyrin and a change in the protonation state of the pH indicator within the film. The same change in spectral properties of the metalloporphyrin occurs in the absence of added pH indicator or with added tetraphenylborate derivative anionic sites, but optical responses to fluoride in these cases are shown to be irreversible. The presence of the pH indicator and the simultaneous fluoride/proton coextraction equilibrium chemistry is shown to greatly enhance the reversibility of fluoride binding to the Al(III) porphyrin. Optical response toward fluoride can be observed in the range of 0.1 microM-1.6 mM. Optical selectivity coefficients of <10(-6) for common anions (e.g., sulfate, chloride, nitrate, etc.) and <10(-4) for perchlorate and thiocyanate are obtained. Measurements of fluoride in drinking water via the new optical sensor are shown to correlate well with values obtained for the same samples using a classical LaF3-based fluoride ion-selective electrode method.


Assuntos
Alumínio/química , Técnicas Biossensoriais/métodos , Fluoretos/química , Membranas Artificiais , Cloreto de Polivinila/química , Porfirinas/química , Concentração de Íons de Hidrogênio , Óptica e Fotônica , Sensibilidade e Especificidade , Água/química
20.
J Am Chem Soc ; 127(15): 5318-9, 2005 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-15826159

RESUMO

A highly selective, sensitive, and reversible fluoride optical sensing film based on aluminum(III)octaethylporphyrin as a fluoride ionophore and a lipophilic pH indicator as the optical transducer is described. The fluoride optical sensing films exhibit a submicromolar detection limit and high discrimination for fluoride over several lipophilic anions such as nitrate, perchlorate, and thiocyanate.


Assuntos
Alumínio/química , Fluoretos/análise , Porfirinas/química , Eletrodos , Éteres/química , Fluoretos/química , Concentração de Íons de Hidrogênio , Lantânio/química , Óptica e Fotônica , Cloreto de Polivinila/química , Potenciometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...